Custom-Cal has a high success rate in the repair of the TEKTRONIX TDS 210. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS 210 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS 210 (TDS210)   Description / Specification:    
TEKTRONIX TDS 210 2 Ch 60 MHz Digital Storage Oscilloscope

60 MHz Digital Storage Oscilloscope. Total Channels: 2. Sample Rate: 1 GS/s on each channel. Sensitivity (with calibrated fine adjustment): 2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode). DC Gain Accuracy: ± 3%. (± 4% at 2 mV/div and 5 mV/div). Vertical Resolution: 8 bits (256 levels over 10.24 vertical divisions). Acquisition Modes: Sample, Average, Peak Detect; High frequency and random glitch capture; captures glitches as narrow as 10 ns using acquisition hardware at all time/div settings between 5 us/div and 5 s/div. Time/Division Range: 5 ns to 5 s/div. Record Length: 2500 sample points per channel. Horizontal Accuracy: ± 0.01 %. Waveform Storage: Two 2500 point reference waveforms. Trigger Type: Edge (Rising or Falling), Video, Set to 50%. Trigger Source: CHI, CH2, Ext, Ext/5 and AC Line. Cursor Types: Voltage, Time. Backlit LCD with adjustable multilevel contrast. GPIB



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS 210. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX TDS 210 REPAIR and/or TEKTRONIX TDS 210 2 Ch 60 MHz Digital Storage Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: